PSIM Word Compare Instructions Introductory Lab
|
Word Comparison Instructions
From the Main Menu of the PSIM program, select the I/O simulation
display.
Toggle Function Key [F2] until the minimum I/O Data Table is displayed
in the upper box of the display, and the Counter Table is displayed in
the lower box of the Data table display.
Select the Rung Editor [F5] and enter the following ladder Logic
program.

Once you have entered your
program, select the Program Utility menu and save your program to
disk. Now exit the Rung Editor and return to the I/O simulation
Display.
Open and Close switch I:1/00 a
number of times and carefully observe the incrementing of C1's
accumalator and the operation of the 3 lights which are controlled
by your program.
Continue incrementing the counter
until the "RES" instruction in rung #2 is activated.
What was the highest count achieved
before the "RES" instruction zeroed the accumalator?
Highest accumalator count: ________
Increment the counter again through
its range and note the accumalator values which allow the lights
O:1/00, O:1/01 and O:1/02 to be energized. Note the values on the
appropriate rungs listed below.

|
|